About Natrox

NATROX® Oxygen Wound Therapy System is a class II medical device licensed under Medical Device Directive 93/42/EEC.
The system consists of two main elements; the NATROX® Oxygen Generator and the NATROX® Oxygen delivery system.

NATROX® Oxygen Generator

The NATROX® Oxygen Generator is a battery-operated device which delivers continuous pure humidified oxygen to the wound bed through water electrolysis. It is supplied with two rechargeable batteries and a charging kit, thus allowing the user complete freedom of movement. Each battery will last for a minimum of 30 hours ; however, users should be advised to keep one on charge whilst using the other and changing them over daily.

NATROX® Oxygen Delivery System

The NATROX® Oxygen Delivery System is a sterile, single-use wound interface. Its “web” like design allows free passage of wound exudate into the secondary dressing whilst optimising the flow and diffusion of oxygen across the wound bed. It has a 1 m long thin flexible tube which connects directly to the NATROX® Oxygen Generator. The NATROX® Oxygen Delivery System should be changed at each dressing change in accordance with good clinical practice. However, it can remain in place for up to 7 days if clinically appropriate.

About

NATROX® Oxygen Wound Therapy System is a class II medical device licensed under Medical Device Directive 93/42/EEC.
The system consists of two main elements; the NATROX® Oxygen Generator and the NATROX® Oxygen delivery system.

NATROX® Oxygen Generator

The NATROX® Oxygen Generator is a battery-operated device which delivers continuous pure humidified oxygen to the wound bed through water electrolysis. It is supplied with two rechargeable batteries and a charging kit, thus allowing the user complete freedom of movement. Each battery will last for a minimum of 30 hours ; however, users should be advised to keep one on charge whilst using the other and changing them over daily.

NATROX® Oxygen Delivery System

The NATROX® Oxygen Delivery System is a sterile, single-use wound interface. Its “web” like design allows free passage of wound exudate into the secondary dressing whilst optimising the flow and diffusion of oxygen across the wound bed. It has a 1 m long thin flexible tube which connects directly to the NATROX® Oxygen Generator. The NATROX® Oxygen Delivery System should be changed at each dressing change in accordance with good clinical practice. However, it can remain in place for up to 7 days if clinically appropriate.

INFORMATION FOR
CLINICIANS

Oxygen is critical to many of the processes
required in wound healing. NATROX® Oxygen
Wound Therapy allows you to prescribe topical
oxygen in a very simple, safe and extremely
convenient way directly to the wound bed.

INFORMATION FOR
PATIENTS

NATROX® Oxygen Wound Therapy is a small
portable device about the size of a mobile
phone. Its function is to produce concentrated
oxygen from the surrounding air, and pass this
down a thin flexible tube directly to a wound
that is failing to progress as expected.